Categories
ROZ-5D
ROZ-5D LUMINAIRE
The ROZ-5D lamp may be used in underground excavations of mines:
- with no methane explosion hazard classified under the "a" class,
- with methane explosion hazard classified under the "b" or "c" class,
- with no coal dust explosion hazard,
- with coal dust explosion hazard of the "A" and "B" class.
The ROZ-5D lamp is classified in the M2 category and its energy supply must be switched off in the event of the formation of an explosive atmosphere.
The ROZ-5D lamp is intended for installation on underground mining locomotives as a main-beam or dipped-beam lamp to illuminate the route or as a red or white position lamp.
Technical parameters |
|
---|---|
Parameter |
Value (unit) |
Supply voltage |
12-24V DC, 42V AC |
Frequency of supply voltage |
0Hz, 50-60Hz |
Rated power |
24W – main beam 12W – dipped beam |
ATEX marking |
|
EC type examination certificate no. |
FTZÚ 15 ATEX 0140X |
Ingress protection |
IP65 |
Source of light |
LEDs |
Luminous flux of the source of light |
3000 lm |
Cable gland |
WKE 14-20 |
Flameproof cap |
72.091 |
Maximum conductor cross-section |
4 mm2 |
Connecting terminals |
KDS 4 (Phoenix Contact) |
Current-carrying capacity of current terminals |
20A |
Protection class |
I |
Ambient temperature |
-10°C to+40°C |
Acceptable humidity (at a temperature +35°C) |
95% |
Weight |
11 kg |
external dimensions (W x H x L) |
155 x 220 x 180 mm – glands from the bottom 155 x 160 x 240 mm – glands from the back |