LGMI-16

LGMI-16 intrinsically safe teletechnical meter

CERTIFICATE:

LGMI-16 intrinsically safe teletechnical meter - a universal measuring device used to test the parameters of underground telecommunication networks and other electrical parameters.

DESCRIPTION

The LGMI-16 intrinsically safe teletechnical meter is a universal measuring device used to test underground parameters of telecommunication networks and other electrical parameters. It enables, among others, assessment of the efficiency of telecommunication networks and the size of interference occurring in the tracks. The device allows for measurements of such parameters as: Alternating and direct voltage Alternating and direct current Resistance Signal attenuation The meter also allows for generation of a sinusoidal signal with a given amplitude and frequency. Measurements are made using the "True RMS" method

FEATURES/TECHNICAL SPECIFICATION
  • DC voltmeter

Range

Resolution

Accuracy

200mV

100μV

±0.5% ±1 digit

2V

1mv

±0.5% ±1 digit

20V

10mV

±0.5% ±1 digit

60V

100mV

±0.5% ±1 digit

  • AC voltmeter (50 – 3400 Hz)

Range

Resolution

Accuracy

200mV

100μV

±1.2% ±3 digits

2V

1mv

±0.8% ±3 digits

20V

10mV

±0.8% ±3 digits

60V

100mV

±0.8% ±3 digits

  • Level meter (300 – 3400 Hz)
    • From 2mV (-51.76 dB) to 200mV (-11.76 dB)
    • From 200mV (-11.76 dB) to 2V (8.24 dB)
    • 0dB = 775mV
  • DC Ammeter

Range

Resolution

Accuracy

2A

1mA

±0.5% ±3 digits

Input impedance: max. 1Ω. Possibility of installing an external shunt

  • DC milliammeter

Range

Resolution

Accuracy

2mA

1μA

±0.8% ±3 digits

20mA

10uA

±0.8% ±3 digits

200mA

100uA

±0.5% ±3 digits

Input impedance: max. 1Ω. Possibility of installing an external shunt

  • AC ammeter (50 – 3400 Hz)

Range

Resolution

Accuracy

2A

1mA

± 3% ± 3 digits

  • AC milliammeter (50 – 3400 Hz)

Range

Resolution

Accuracy

2mA

1μA

± 1% ± 3 digits

20mA

10uA

± 1% ± 3 digits

200mA

100uA

±2% ±3 digits

  • Ohmmeter

Range

Resolution

Accuracy

200Ω

0.1Ω

±0.8% ±3 digits

2kΩ

±0.8% ±1 digit

20kΩ

10 Ohm

±0.8% ±1 digit

200kΩ

100Ω

±0.8% ±1 digit

2MΩ

1kΩ

±0.8% ±1 digit

  • Gigaohmmeter

Range

Resolution

Accuracy

20MΩ

10kΩ

± 2% ± 2 digits

200MΩ

100kΩ

± 2% ± 2 digits

2GΩ

1MΩ

± 10% ± 2 digits

  • Generator
    • Frequency range 300 - 3400Hz
    • Voltage range: 1mV - 1V

  • Circuit Continuity Test (with sound)

ADDITIONAL FEATURES

  • Large graphic display showing precise measurement parameters

  • Intuitive menu
  • Handy, compact design

Dear User, we use cookies to ensure that our services are of the highest quality and that they meet your individual needs. They can also be used by research and advertising companies cooperating with us. If you continue to browse our website without changing your settings, we will assume that you accept our cookie policy.