Categories
SLOGAN-SS/08
SLOGAN-SS/08 LIGHT SIGNALS

The signal displays optical "stop" or "go" signals on underground railway routes.
The device is ready to work after connecting the power supply and the control signal and confirmation signal to it. The signal is controlled via the control input. If we apply a voltage equal to the supply voltage (11-15.8V) to this input, the green light will turn on - "drive". The red light - "stop" will turn on if we apply a voltage of 0V to this input in relation to the system mass or if the control wire is damaged (broken).
The indicator, thanks to its confirmation output, allows for obtaining feedback on the currently lit optical signal. If the red light is on, the feedback signal has a level equal to the supply voltage level. If the green indicator is on, the feedback signal reaches a level of 0V in relation to the system ground.
Supply voltage (terminals a, b of connector Z2) | 11 - 15.8V | |
Maximum current consumption | 80mA | |
Control voltage (terminal b of connector Z1 and b of Z2) | 11 - 15.8V | |
Control current consumption (terminal b of Z1 and b of Z2 connectors) | 20mA | |
Input circuit parameters | terminals 1, 2 terminal 3 of connector P1 (input) terminal 4 of connector P1 (output) | Ui = 15.8V, Ii = 0.7A, Li = 0, Ci = 0 Ui = 15.8V, Ii = 0.7A, Li = 0, Ci = 0 Uo = 15.8V, Io = 0.7A, Lo = 0, Co = 0 |
Outer diameter of connecting cables | 6 to 12mm | |
Core cross-section of connecting cables | 1.5mm2 | |
Operating temperature range | -20ºC - +40ºC | |
Relative humidity at 40° C | up to 95% | |
Degree of protection | IP54 | |
Power supply | Ex power supply (ZSI-94/1) | |
Dimensions | 430x265x80mm | |
Mass | approx. 8 kg | |
EC Type Examination Certificate No.: | FTZU 07 ATEX 0217X | |
Explosion-proof construction feature | Ex I M2 Ex ib I |